GTC-11 | 1-11/16” Gamma Ray\Temperature\CCL Tool with Negative Feed Through

The DSS 1 11/16” Is a multi purpose pulse Tool (GTC). It includes a platinum RTD (Resistance Temperature Detector) which provides high resolution data with fast temperature response. This tool also includes a Sodium Iodide scintillation crystal and photomultiplier tube which demonstrate high sensitivity and resolution. The tool has a magnetic casing collar locator. The tool also has a standard GO connector on the bottom and when a negative voltage is applied at the cable head, the negative voltage is routed directly to bottom connector. This function allows a noise tool to be used at the bottom.

Request Quote
Description
Reviews (0)

Applications

  • Borehole fluid temperature.
  • Depth correlation.
  • Combine two services in one run.
  • Noise logging when a noise tool is attached.

Features

  • Rated for high-temperature and high-pressure environments.
  • Inline temperature probe.
  • CCL outputs a line shake signal to the surface.
  • Temperature tool outputs positive pulses calibrated to 20 counts/°C.
  • Gamma Ray tool outputs negative pulses of actual Gamma Ray detector.
  • Gamma Ray has a maximum output of 5000 counts.
  • Can be used with a negative powered noise tool attached to the bottom connector.
  • When a negative voltage is applied at the cable head, the negative voltage is routed directly to the bottom of the tool.
  • Compatible with most surface systems.
  • Designed to make pulse conflicts impossible.
  • Electronic design verified for 1 hour operation at 415°F to ensure reliability.
  • H2S resistant materials.

Specifications

Tool Operating Voltage 100-150 VDC Tool Length (make-up) 141.4 cm (55.66 in)
Tool Operating Current 50-60 mA Tool Length (shipping) 150 cm (59.34 in)
Output Pulses Amplitude Pos. & Neg. ~10 VDC Tool Weight 10.8 Kg (24.0 Lb)
Output Pulses Width 25 µS 0 to 5000 Count Gamma Ray Point from Top of Tool
Max. Pressure 172.4 Mpa (25 000 PSI) CCL Point from Top of Tool
Max. Temperature 204°C (400°F) Borehole Fluids Any
Tool Diameter – OD 42.85 mm(1 11/16 in) Top End Connector Contact Socket Go Female

 

Reviews

There are no reviews yet.

Be the first to review “GTC-11 | 1-11/16” Gamma Ray\Temperature\CCL Tool with Negative Feed Through”